Adam Dickson

Firewall cable glands

2 x choke cable 5mm

  • Multicomp PP001666 PG7 (12.5mm hole) 3-6.5mm cable fit


1 x cabin heat cable 5mm

  • Multicomp PP001666 PG7 (12.5mm hole) 3-6.5mm cable fit


2 x throttle cables 6mm

  • Multicomp PP001667 PG9 (15.2mm hole) 4-8mm cable fit


1 x passthrough for 22000uF electrolytic - 2 x 14AWG wires (2.3-2.4mm diam insulation)

  • Multicomp PP001666 PG7 (12.5mm hole) 3-6.5mm cable fit


1 x passthrough for engine sensor and control cables

  • 3 x pressure sensors - 9 x 20AWG 1.5-1.6mm diam
  • 2 x temp sensors - 4 x 20AWG 1.5-1.6mm diam
  • 2 x magneto grounding cables, each shielded 1-core tefzel
  • 1 x start solenoid wire 20AWG1.5-1.6mm diam
  • 1 x main ground wire 12 AWG 2.8-2.9mm diam
  • 1 x main positive wire 12 AWG 2.8-2.9mm diam
  • 4 x EGT sensors - 8 x 20AWG 1.5-1.6mm diam


Estimated, either of these

  • Multicomp PP001670 PG16 (22.5mm hole) 10-14mm cable fit
  • Multicomp PP001671 PG21 (28.3mm hole) 13-18mm cable fit