Relabelling of flap connector wires
A previous post
https://webuildplanes.com/adam-dickson-sling2/p/7381/diagnosis-of-flap-potentiometer-problem
documents the non-optimal labelling of the wires at the connector right at the actuator:
- white with blue stripe (revised) labelled "BLU" connects to white transmotec wire -> P5 aft sensor gnd connects to GND of potentiometer
- white with orange stripe labelled "YEL" connects to yellow transmotec wire -> P18 +5 AUX connects to V input of potentiometer
- white wire (revised) labelled "WHT" connects to blue transmotec wire -> P22 flap position input connects to wiper of potentiometer
- red wire connects to red transmotec wire
- green wire connects to black transmotec wire
Now that I have the midsection partly disassembled giving better access to the connector, I am relabelling the wires as follows, in such a way that the labels match the wire colours on the transmotec actuator side
- white with blue stripe now labelled labelled "WHT" connects to white transmotec wire -> P5 aft sensor gnd connects to GND of potentiometer
- white with orange stripe labelled "YEL" connects to yellow transmotec wire -> P18 +5 AUX connects to V input of potentiometer
- white wire now labelled "BLU" connects to blue transmotec wire -> P22 flap position input connects to wiper of potentiometer
- red wire now labelled "RED" - connects to red transmotec wire
- green wire now labelled "BLK" - connects to black transmotec wire
This convention will assist correct wiring if the actuator is ever replaced
This post is from Adam Dickson